{"id":433,"date":"2026-04-19T07:04:32","date_gmt":"2026-04-19T07:04:32","guid":{"rendered":"https:\/\/designforfacade.com\/?page_id=433"},"modified":"2026-04-24T08:59:49","modified_gmt":"2026-04-24T08:59:49","slug":"sky-garden","status":"publish","type":"page","link":"https:\/\/designforfacade.com\/en\/sky-garden\/","title":{"rendered":"Consulting. LONDON&#8217;S SKY GARDEN"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"433\" class=\"elementor elementor-433\">\n\t\t\t\t<div class=\"elementor-element elementor-element-18e25df e-flex e-con-boxed e-con e-parent\" data-id=\"18e25df\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8d3aa2d elementor-widget elementor-widget-image\" data-id=\"8d3aa2d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1788\" height=\"2560\" src=\"https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/03\/Portfolio-1-scaled.png\" class=\"attachment-full size-full wp-image-188\" alt=\"\" srcset=\"https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/03\/Portfolio-1-scaled.png 1788w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/03\/Portfolio-1-210x300.png 210w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/03\/Portfolio-1-715x1024.png 715w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/03\/Portfolio-1-768x1099.png 768w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/03\/Portfolio-1-1073x1536.png 1073w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/03\/Portfolio-1-1431x2048.png 1431w\" sizes=\"(max-width: 1788px) 100vw, 1788px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e1f23c5 e-flex e-con-boxed e-con e-parent\" data-id=\"e1f23c5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a574ce7 elementor-widget elementor-widget-spacer\" data-id=\"a574ce7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-40ffa5a elementor-widget elementor-widget-text-editor\" data-id=\"40ffa5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Project Description<\/strong><\/h3><p>As part of a consultancy project, the glass roof of the Sky Garden on the top three floors of the 20 Fenchurch Street building in London was inspected.<\/p><p>The client commissioned a detailed analysis due to existing water infiltration in the roof structure.<\/p><p>The aim of the investigation was to identify possible causes and to assess the performance of the existing fa\u00e7ade and roof details.<\/p><h3><strong>Analysis &amp; Approach <\/strong><\/h3><p>The investigation was based on a detailed desk study of the relevant structural details and the known construction conditions.<\/p><p>In addition, a site visit was carried out to inspect the existing construction on site and to assess the actual performance of the structure.<\/p><h3><strong>Provided Tasks<\/strong><\/h3><ul><li>Analysis of the existing glass roof structure above the Sky Garden<\/li><li>Investigation of structural details in the waterproofing area<\/li><li>Assessment of the quality of workmanship and the building physics-related factors<\/li><li>Conducting an on-site inspection to assess the current condition.<\/li><li>Derivation of reports and technical findings for the root cause analysis of the leaks<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Projektbeschreibung Im Rahmen eines Consulting-Auftrags wurde das Glasdach des Sky Garden auf den obersten drei Etagen des 20 Fenchurch Street Buildings in London untersucht. Der Auftraggeber beauftragte eine detaillierte Analyse aufgrund von bestehenden Wasserinfiltrationen in der Dachkonstruktion. Ziel der Untersuchung war die Identifikation m\u00f6glicher Ursachen sowie die Bewertung des Verhaltens der bestehenden Fassaden- und Dachdetails. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-433","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/pages\/433","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/comments?post=433"}],"version-history":[{"count":10,"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/pages\/433\/revisions"}],"predecessor-version":[{"id":578,"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/pages\/433\/revisions\/578"}],"wp:attachment":[{"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/media?parent=433"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}