{"id":414,"date":"2026-04-19T06:58:46","date_gmt":"2026-04-19T06:58:46","guid":{"rendered":"https:\/\/designforfacade.com\/?page_id=414"},"modified":"2026-04-24T08:58:53","modified_gmt":"2026-04-24T08:58:53","slug":"neuhauser","status":"publish","type":"page","link":"https:\/\/designforfacade.com\/en\/neuhauser\/","title":{"rendered":"Fassadenplanung. Neuhauser 23"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"414\" class=\"elementor elementor-414\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1514f2f e-flex e-con-boxed e-con e-parent\" data-id=\"1514f2f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1f6aa39 elementor-widget elementor-widget-image\" data-id=\"1f6aa39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"2381\" height=\"1684\" src=\"https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/04\/Neuhauser.png\" class=\"attachment-full size-full wp-image-471\" alt=\"\" srcset=\"https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/04\/Neuhauser.png 2381w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/04\/Neuhauser-300x212.png 300w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/04\/Neuhauser-1024x724.png 1024w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/04\/Neuhauser-768x543.png 768w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/04\/Neuhauser-1536x1086.png 1536w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/04\/Neuhauser-2048x1448.png 2048w, https:\/\/designforfacade.com\/wp-content\/uploads\/2026\/04\/Neuhauser-18x12.png 18w\" sizes=\"(max-width: 2381px) 100vw, 2381px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-896dc95 e-flex e-con-boxed e-con e-parent\" data-id=\"896dc95\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-82b61b1 elementor-widget elementor-widget-spacer\" data-id=\"82b61b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2cfffcf elementor-widget elementor-widget-text-editor\" data-id=\"2cfffcf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Project Description<\/strong><\/h3><p>As part of the refurbishment of an existing commercial building, a new fa\u00e7ade structure was developed, comprising individual window and design elements that blend harmoniously into the existing architecture.<\/p><p>Besondere Anforderungen ergaben sich im Bereich der gro\u00dfformatigen Panoramafenster im ersten Obergeschoss, die f\u00fcr die Gewerbenutzung eine zentrale gestalterische und konstruktive Rolle spielen.<\/p><h3><strong>Technical Solution<\/strong><\/h3><p>The window structure is supported by cantilevered steel profiles that transfer the loads into the existing reinforced concrete structure.<\/p><p>The large-format windows on the first floor protrude from the fa\u00e7ade plane, thereby creating a structural situation in which rainwater from the floors above is channelled onto these areas.<\/p><p>This led to specific requirements regarding the design of the upper connection details and the safe drainage of rainwater in the fa\u00e7ade area.<\/p><h3><strong>Provided Tasks<\/strong><\/h3><ul><li>Development of structural details for fa\u00e7ade drainage at the top of the panoramic windows with integrated drainage canal<\/li><li>Thermal analysis of the connection areas (isotherm distribution) to prevent condensation<\/li><li>Optimisation of the thermal performance of the fa\u00e7ade connections<\/li><li>Conducting thermal simulations using WinIso (Sommer Informatik)<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Projektbeschreibung Im Rahmen der Umgestaltung eines bestehenden Gesch\u00e4ftsgeb\u00e4udes wurde eine neue Fassadenstruktur entwickelt, die sich aus einzelnen Fenster- und Gestaltungselementen zusammensetzt und sich harmonisch in die bestehende Architektur integriert. Besondere Anforderungen ergaben sich im Bereich der gro\u00dfformatigen Panoramafenster im ersten Obergeschoss, die f\u00fcr die Gewerbenutzung eine zentrale gestalterische und konstruktive Rolle spielen. Technische L\u00f6sung Die [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-414","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/pages\/414","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/comments?post=414"}],"version-history":[{"count":14,"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/pages\/414\/revisions"}],"predecessor-version":[{"id":575,"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/pages\/414\/revisions\/575"}],"wp:attachment":[{"href":"https:\/\/designforfacade.com\/en\/wp-json\/wp\/v2\/media?parent=414"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}